1328
Module 9184 Re-enable locked NC key groups by PLC
The module cancels the effect of Module 9183 for the given key group. The
table at the end of this section contains the assignment of the keys to the key
groups.
The key-group codes are:
0: All keys
1: ASCII
2: Soft keys, Page Up/Down
3: Cursor, ENT, NOENT, DEL, END, GOTO
4: Numbers, algebraic signs, decimal point, actual position capture
5: Operating modes
6: Block opening keys
Call:
PS
B/W/D/K <Key-group code>
CM
9184
PL
B/W/D
<Error status>
0: Group of NC keys enabled
–1: Transferred parameter > maximum value
Error recognition:
Marker
Value
NN_GenApiModule
0
Error
1
NN_GenApiModule
2
ErrorCode
Meaning
Disabling was canceled
Error code in NN_GenApiModuleErrorCode
Transferred parameter invalid
HEIDENHAIN Technical Manual MANUALplus 620

Advertisement

loading