7.2.5
A50010-Y3-C150-2-7619
To display the information of peer host using OAM function, use the following command.
Command
oam remote alarm optical <1-3>
<0-65535> PORTS
oam remote alarm temperature
<0-255> PORTS
oam remote alarm voltage { min |
max } <0-65535> PORTS
oam remote electrical mode { full
| half } PORTS
oam remote general autonego
<1-4> { enable | disable } PORTS
oam remote general forwarding
<3-4> { enable | disable } PORTS
oam remote general speed <1-
4> <0-4294967295>PORTS
oam remote general user <1-4>
STRING PORTS
oam remote system interface
{ unforced | forceA | forceB }
PORTS
oam remote system interval <0-
255> PORTS
oam
remote
system
{ master | slave } PORTS
oam
remote
system
PORTS

Displaying OAM Configuration

To display OAM configuration, use the following command.
Command
show oam
show oam local [PORTS]
show oam remote [PORTS]
show oam remote variable <0-
255> <0-255> PORTS
show oam remote variable spe-
<0-255>
<0-255>
cific
PORTS
Mode
Shows the information of peer host using OAM func-
Bridge
tion.
mode
reset
Mode
Shows OAM configuration.
Shows local OAM configuration.
Shows remote OAM configuration.
Enable
Global
Shows remote OAM variable.
Bridge
<0-4>
Shows remote OAM specific variable.