Siemens S223 User Manual page 82

Siemens single-board fast ethernet switch operators user manual
Table of Contents

Advertisement

UMN:CLI
82
Step 4
To delete and modify the configuration, use the following command.
Command
mirror disable
mirror del PORTS [ ingress |
egress ]
Step 5
To disable monitoring function, use the following command.
Command
no mirror monitor
The following is an example of configuring port mirroring with a port.
Step 1
Connect a motoring PC to the monitor port of the switch.
Step 2
Enable mirroring function.
SWITCH(bridge)# mirror enable
SWITCH(bridge)#
Step 3
Configure the monitor port 1 and mirroring port 2, 3, 4 and 5.
SWITCH(bridge)# mirror monitor 1
SWITCH(bridge)# mirror add 2
SWITCH(bridge)# mirror add 3-5
SWITCH(bridge)#
Step 4
Check the configuration.
SWITCH(bridge)# show mirror
Mirroring enabled
Monitor port =
-----------------------------------
-----------------------------------
Ingress Mirrored Ports|............
Egress Mirrored Ports|............
SWITCH(bridge)#
SURPASS hiD 6615 S223/S323 R1.5
Mode
Deactivate monitoring.
Bridge
Delete a port from the mirrored ports.
Mode
Bridge
Disable port mirroring function.
|
1
|123456789012
User Manual
Description
Description
A50010-Y3-C150-2-7619

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S323Surpass hid 6615 s223Surpass hid 6615 s323 r1.5

Table of Contents