Enabling SNMP Trap

The system provides various kind of SNMP trap, but it may inefficiently work if all these
trap messages are sent very frequently. Therefore, you can select each SNMP trap sent
to an SNMP trap host.
The system is configured to send all the SNMP traps as default.
authentication-failure is shown to inform wrong community is input when user trying
to access to SNMP inputs wrong community.
cold-start is shown when SNMP agent is turned off and restarts again.
link-up/down is shown when network of port specified by user is disconnected, or
when the network is connected again.
memory-threshold is shown when memory usage exceeds the threshold specified
by user. Also, when memory usage falls below the threshold, trap message will be
shown to notify it.
cpu-threshold is shown when CPU utilization exceeds the threshold specified by
user. Also, when CPU load falls below the threshold, trap message will be shown to
notify it.
port-threshold is shown when the port traffic exceeds the threshold configured by
user. Also, when port traffic falls below the threshold, trap message will be shown.
temperature-threshold is shown when the system temperature exceeds the thresh-
old configured by user. Also, when system temperature falls below the threshold, trap
message will be shown.
dhcp-lease is shown when there is no more IP address can be assigned in subnet of
DHCP server. Even if only one subnet does not have IP address to assign when
there are several subnets, this trap message will be seen.
fan/power/module is shown when there is any status-change of fan, power, and
module.
To enable SNMP trap, use the following command.
Command
snmp trap auth-fail
snmp trap cold-start
snmp
trap
link-up
[NODE]
snmp trap link-down PORTS
[NODE]
snmp trap cpu-threshold
snmp trap port-threshold
snmp trap temp-threshold
Command
Mode
Configures the system to send SNMP trap when SNMP
authentication is fail.
Configures the system to send SNMP trap when SNMP
agent restarts.
Configures the system to send SNMP trap when a port
PORTS
is connected to network.
Configures the system to send SNMP trap when a port
Global
is disconnected from network.
Configures the system to send SNMP trap when CPU
load exceeds or falls below the threshold.
Configures the system to send SNMP trap when the
port traffic exceeds or falls below the threshold.
Configures the system to send SNMP trap when sys-
tem temperature exceeds or falls below the threshold.
Mode
SURPASS hiD 6615 S223/S323 R1.5
Description
Description
A50010-Y3-C150-2-7619