Step 2
To enable the MGMT interface to communicate with TFTP server, you need to configure a
proper IP address, subnet mask and gateway on the interface.
To configure an IP address, use the following command.
Command
ip A.B.C.D
ip
To configure a subnet mask, use the following command.
Command
netmask A.B.C.D
netmask
To configure a default gateway, use the following command.
Command
gateway A.B.C.D
gateway
To display a configured IP address, subnet mask and gateway, use the following com-
mand.
Command
show
The configured IP address, subnet mask and gateway on the MGMT interface are limited
to the boot mode only!
The following is an example of configuring an IP address, subnet mask and gateway on
the MGMT interface in the boot mode.
Boot> ip 10.27.41.83
Boot> netmask 255.255.255.0
Boot> gateway 10.27.41.254
Boot> show
IP
= 10.27.41.83
GATEWAY
= 10.27.41.254
NETMASK
= 255.255.255.0
MAC
= 00:d0:cb:00:0d:83
MAC1
= ff:ff:ff:ff:ff:ff
Boot>
Mode
Configures an IP address.
Boot
Shows a currently configured IP address.
Mode
Configures a subnet mask. (e.g. 255.255.255.0)
Boot
Shows a currently configured subnet mask.
Mode
Configures a default gateway.
Boot
Shows a currently configured default gateway.
Mode
Shows a currently configured IP address, subnet mask
Boot
and gateway.