Step 2
Configure the network to operate as RIP.
Command
network {A.B.C.D/M | INTER-
FACE }
no network {A.B.C.D/M | INTER-
FACE }
The command network enables RIP interfaces between certain numbers of a special
network address. For example, if the network for 10.0.0.0/24 is RIP enabled, this would
result in all the addresses from 10.0.0.0 to 10.0.0.255 being enabled for RIP.
By the way, it's not possible to exchange the RIP routing information if it hasn't been es-
tablished RIP network using network command even though interface belongs to RIP
network. RIP packets with RIP routing information is transmitted to port specified with the
network command.
After RIP is enabled, you can configure RIP with the following items:
RIP Neighbor Routers
RIP Version
Creating available Static Route only for RIP
Redistributing Routing Information
Metrics for Redistributed Routes
Administrative Distance
Originating Default Information
Routing Information Filtering
Maximum Number of RIP Routes
RIP Network Timer
Split Horizon
Authentication Key
Restarting RIP
UDP Buffer Size of RIP
Monitoring and Managing RIP

RIP Neighbor Router

Since RIP is broadcast protocol, routers should be connected each other to transmit the
routing information of RIP to non-broadcast network.
To configure neighbor router to transmit RIP information, use the following command on
Router Configuration mode.
SURPASS hiD 6615 S223/S323 R1.5
Mode
Establishes the network to operate as RIP.
A.B.C.D/M: IP prefix (e.g. 35.0.0.0/8)
INTERFACE: interface name