8.5.1
8.5.2
A50010-Y3-C150-2-7619

Configuring Rate Limit

To set a port bandwidth, use the following command.
Command
rate PORTS RATE [ egress | in-
gress ]
no rate PORTS
no rate PORTS [ egress | ingress ]
Unless you input neither egress nor ingress, they are configured to be same. To switch,
egress is incoming packet. To display the configured bandwidth, use the following com-
mand.
Command
show rate

Sample Configuration

The following is an example of showing the configuration after setting the bandwidth of
64Mbps to port number 1 and 128Mbps to the port number 2.
SWTICH(bridge)# rate 1 64
SWTICH(bridge)# rate 2 128
SWTICH(bridge)# show rate
unit : kbps E : Enhanced
------------------------------------------------------------------------------
Port |
Ingress
------------------------------------------+-----------------------------------
1 |
64
3 |
N/A
5 |
N/A
7 |
N/A
SWTICH(bridge)#
Mode
Sets port bandwidth. If you input egress or ingress, you
can configure outgoing packet or incoming packet. The
unit is 64 Kbps.
Bridge
Clears rate configuration of a specific port.
Clears rate configuration of a specific port by transmit-
ting direction.
Mode
Global
Shows the configured bandwidth.
|
Egress
| Port |
|
64
|
2 |
|
N/A
|
4 |
|
N/A
|
6 |
|
N/A
|
8 |
Description
Description
Ingress
|
Egress
128
|
128
N/A
|
N/A
N/A
|
N/A
N/A
|
N/A
UMN:CLI