Manual Switch to Secondary

To configure Manual Switch to Secondary, use the following command.
Command
erp ms-s DOMAIN-ID
To disable Manual Switch to Secondary, use the following command.
Command
no erp ms-s DOMAIN-ID

Wait-to-Restore Time

To configure Wait-to-Restore Time, use the following command.
Command
erp wait-to-restore DOMAIN-ID
<1-720>
To return the configured Wait-to-Restore Time as Default, use the following command.
Command
no erp wait-to-restore DOMAIN-
ID

Learning Disable Time

To configure ERP Learning Disable Time, use the following command.
Command
erp learn-dis-time DOMAIN-ID
<0-500>
To return the configured Learning Disable Time as Default, use the following command.
Command
no erp learn-dis-time DOMAIN-ID

Test Packet Interval

To configure ERP Test Packet Interval, use the following command.
Command
erp
test-packet-interval
MAIN-ID <10-500>
Mode
Bridge
Configures ERP manual switch to secondary
Mode
Bridge
Disables ERP manual switch to secondary
Mode
Configures ERP wait-to-restore time
Bridge
1-720: Wait to restore time in second
Mode
Bridge
Configures ERP wait-to-restore time as default value
Mode
Configures ERP learning disable time
Bridge
0-500: learning disabling time (unit: millisecond)
Mode
Bridge
Configures ERP learning disable time as default value
Mode
Configures ERP test packet interval
DO-
Bridge
10-500: packet interval (unit: millisecond)