Epson RC180 Manual page 211

Robot controller
Hide thumbs Also See for RC180:
Table of Contents

Advertisement

No.
Message
Ethernet failure. No specification of
2905
Server/Client.
2906
Ethernet port was not configured.
Ethernet port was already in use by
2907
another task.
Cannot change the port parameters
2908
while the Ethernet port is open.
2909
Ethernet port is not open.
2910
Timeout reading from an Ethernet port.
2911
Failed to read from an Ethernet port.
Ethernet port was already open by
2912
another task.
2913
Failed to write to the Ethernet port.
Ethernet port connection was not
2914
completed.
Data received from the Ethernet port is
2915
beyond the limit of one line.
RS-232C
failure.
2920
process error.
RS-232C failure. Uncommon error.
2921
RS-232C port read process error.
The RS-232C port hardware is not
2926
installed.
RS-232C port is already open by
2927
another task.
Cannot change the port parameters
2928
while the RS-232C port is open.
2929
RS-232C port is not open.
Timeout reading from the RS-232C
2930
port.
2931
Failed to read from the RS-232C port.
RS-232C port is already open by
2932
another task.
2933
Failed to write to the RS-232C port.
RS-232C
port
2934
completed.
Data received from the RS-232C port
2935
is beyond the limit of one line.
Cannot
execute
2937
RS-232C are useing.
Daemon failure. Failed to create the
2950
daemon thread.
Daemon
failure.
2951
creating the daemon thread.
TEACH/AUTO switching key input
2952
signal failure was detected.
RC180 Rev.17
Review the program.
Check whether the Ethernet port is set
properly.
A single port cannot be used by more
than one task.
The port parameters cannot be changed
while the port is open.
To use the Ethernet port, execute the
OpenNet statement.
Check the communication.
Check the communication.
A single port cannot be used by more
than one task.
Check whether the Ethernet port is set
properly.
cable is connected properly.
Check
communication recipient is open.
The maximum length of a line is 255
bytes.
RS-232C
port
Check whether the RS-232C board is
correctly detected.
Check
communication.
Check whether the RS-232C board is
correctly detected.
A single port cannot be used by more
than one task.
The port parameters cannot be changed
while the port is open.
To use the RS-232C port, execute the
OpenCom statement.
Check the communication.
Check the communication.
A single port cannot be used by more
than one task.
Check the communication.
connection
not
Check the RS-232C port.
The maximum length of a line is 255
bytes.
while
Remote
Specified port is currently used.
Specify another port.
Reboot the Controller.
Timeout
while
Reboot the Controller.
Set the TP key switch to TEACH or
AUTO properly. Check whether the TP
is connected properly.
Maintenance 8. Trouble Shooting
Remedy
Check whether the Ethernet
whether
the
port
the
parameter
and
Note 1
Note 2
Port number
Port number
Port number
Port number
Timeout value
Port number
Port number
of
Port number
The number of
bytes
in
a
received line
Port number
Port number
Port number
Port number
Timeout value
Port number
Port number
The number of
bytes
in
a
received line
199