Epson RC180 Manual page 247

Robot controller
Hide thumbs Also See for RC180:
Table of Contents

Advertisement

Vision
No.
Message
Vision Communication.
7300
Server mode not supported.
Vision Communication.
7302
Failed to read from the camera.
Vision Communication.
7303
Read data overflow.
Vision Communication.
7304
Failed to open the Ethernet port.
Vision Communication.
7305
Invalid IP address of camera.
Vision
Communication.
7306
specification of Server/Client.
Vision Communication.
7307
Failed to send to the camera.
Vision Communication.
7308
Camera version is old.
Vision Communication.
7321
Camera setting has not been set.
Vision Communication.
7322
Read timeout.
Vision Communication.
7323
Read invalid data.
Vision Communication.
7324
Failed to send to the camera.
Vision Communication.
7325
Connection is not completed.
Vision Communication.
7326
Read data is too long.
Vision Communication.
7327
Undefined vision sequence.
Vision Communication.
7328
Camera setting has not been set.
Vision Communication.
7329
Vis file is not found.
Vision Communication.
7330
Failed to allocate memory.
Vision Communication.
7341
Out of max camera number.
Vision Communication.
7342
Invalid camera number.
Vision Communication.
7343
VSet parameter is too long.
Vision Communication:
7344
Too many parameters for VGet.
Vision Communication.
7345
Not enough data for VGet statement
variable assignment.
Vision Communication.
7346
Cannot execute a Vision statement
from the command window.
7500
Smart camera. Out of memory.
7501
Smart camera. Project does not exist.
RC180 Rev.17
Remedy
Check the connection with the camera.
Data exceeding the receive buffer was
received.
Check the connection with the camera.
Rebuild the project. Check the camera
configuration.
No
Check the connection with the camera.
The version of the connected camera is
old. Update the camera.
Rebuild the project. Check the camera
configuration.
Check the connection with the camera.
Check the connection with the camera.
Check the connection with the camera.
Check the connection with the camera.
Check the sequence name.
Rebuild the project. Check the camera
configuration.
Rebuild the project. Check the camera
configuration.
Reduce the number of sequences,
objects, and calibration.
Review the camera registration.
Review the camera registration.
Review the names and string variables of
sequences, objects, and calibration.
The number of specified variables is
exceeding 32.
Reduce the number of
parameters.
Reboot the camera.
Check the version of the camera.
Execute the command from the program.
Initialize the camera.
Reduce the project size.
Rebuild the project.
Maintenance 8. Trouble Shooting
Note 1
Note 2
235

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents