Epson RC180 Manual page 79

Robot controller
Hide thumbs Also See for RC180:
Table of Contents

Advertisement

For details of the controller preferences, refer to EPSON RC+ 7.0 User's Guide
[Setup]-[System Configuration]-[Controller]-[Preferences] in 5.12.2 [System Configuration] Command
(Setup Menu).
Preferences (1)
0
0
0
0
1
1
1
1
RC180 Rev.17
Preferences (2)
ForcePowerLow
0
0
1
1
0
0
1
1
Setup & Operation 11. I/O Remote Settings
All tasks and
commands
1→0
Stop
0→1
Stop
1→0
Continue
0→1
Temp. stop
1→0
Stop
0→1
Stop
1→0
Temp. stop
0→1
Continue
Power mode
PowerHigh
Low only
Accept
Not accept
Low only
Accept
High/Low
Low only
Not accept
Low only
Not accept
Accept
Low only
Low only
Not accept
High/Low
Accept
67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents