Setup & Operation 3. Installation

3.3.2 AC Power Cable

■ Make sure that cable manufacturing and connection are done by a qualified
personal.
When proceeding, be sure to connect the earth wire of the AC power cable
colored green/yellow on the Controller to the earth terminal of the factory power
supply. The equipment must be grounded properly at all times to avoid the risk
WARNING
of electric shock. Always use a power plug and receptacle for power connecting
cable. Never connect the Controller directly to the factory power supply. (Field
wiring)
To Controller
The AC plug in not attached to the AC power cable delivered at shipment.
Refer to the wire connection specification and attach a proper plug to the cable that is
suitable for the factory power supply. (A plug is prepared as option.)
Cable Wire Connection Specification
AC power wire (2 cables)
Ground wire
Cable length: 3 mm (Standard)
For RC180-UL
■ Branch Circuit protection (Rated current: 15 A or less) shall be installed in the
external AC power supplying side in accordance with the National Electrical Code.
A disconnecting means shall be installed in accordance with the National Electrical
WARNING
Code and provide the ability for lockout and tagout.
26
Purpose
Black
Green / Yellow
Plug (Set by the users)
M4 Ring solderless terminal
(RC180-UL: M5 Ring solderless terminal)
Color
RC180 Rev.17