Epson RC180 Manual page 249

Robot controller
Hide thumbs Also See for RC180:
Table of Contents

Advertisement

GUI Builder
No.
Message
Cannot
execute
7600
statement from the command window.
7602
GSet parameter is too long.
7603
Too many parameters for GGet.
Not enough data for GGet statement
7604
variable assignment.
The event task cannot be executed.
7610
System
in
EventTaskType is Normal.
The event task cannot be executed.
7611
Safeguard is open and EventTaskType
is Normal.
The event task cannot be executed.
7612
Estop is active and EventTaskType is
not NoEmgAbort.
The event task cannot be executed.
7613
System
in
EventTaskType is not NoEmgAbort.
7650
Invalid property.
7651
Invalid form.
7652
Invalid control.
7653
The specified form is already open.
7654
Event function does not exist.
7655
The item does not exist.
7656
Invalid property value.
MDL failure.
7847
Failed to open the MDL file.
MDL failure.
7848
Failed to read the MDL file.
RC180 Rev.17
a
GUI
Builder
GUI Builder commands are only available in
the program.
Correct the parameter to the proper length.
Check the number of parameters.
Specify the variable.
The system can be operated by changing
pause
state
and
EventTaskType to "NoPause"
The system can be operated by changing
EventTaskType to "NoEmgAbort"
The system can be operated by changing
EventTaskType to "NoEmgAbort"
The system can be operated by changing
error
state
and
EventTaskType to "NoEmgAbort"
Specify the valid property.
Specify the valid form.
Specify the valid control.
Modify the program to avoid double launch.
Check the function name set for the event.
Specify the valid item.
Check the property value and specify the valid
value.
Reboot the controller.
Reinstall the firmware.
Reboot the controller.
Reinstall the latest firmware version.
Maintenance 8. Trouble Shooting
Remedy
Note 1
Note 2
-
-
-
-
237