Technical Data; General Data; Unit-Specific Data; Rated Data Of Supply Modules - Lenze 9215 Operating Instructions Manual

9200 series servo controller
Table of Contents

Advertisement

2.
2.1.
Enclosure
Noise immunity:
Influence of installation height on
rated current:
Ambient temperature
Permissible humidity
Permissible pollution
2.2.

2.2.1. Rated data of supply modules

Supply module type
Mains voltage
DC-bus voltage
(at rated current)
Mains current
Permanent power
(at V
mains
Peak power
(t=5 s)
Permanent brake power (with int.
brake resistor)
Permanent brake power (with
appropriate ext. brake resistor)
Peak brake power
with int. or ext. brake resistor
min. permissible resistance for int.
or ext. brake resistor
Power loss (without brake resistor)
Weight
With low mains voltages, the permissible permanent power is reduced to P zul = P n ⋅ V mains / 480 V
1)
6

Technical data

General data

Steel sheet housing, IP20 to DIN 40050
Severity 4 to IEC 801-4
1000 m: 100% rated current
2000 m: 95% rated current
3000 m: 90% rated current
4000 m: 85% rated current
0 °C...+45 °C during operation
-25 °C...+55 °C during storage
-25 °C...+70 °C during transport
relative humidity 80%, no condensation
Pollution strength 2 to VDE 0110, part 2.
Do not expose units to corrosive or explosive gases.

Unit-specific data

Order no.
1)
= 3 x 480 V)
9212_E
33.9212_E
[V]
3 x 480; 50 - 60 Hz
permissible range 3 x 330...528 ± 0%;
[V]
[A eff ]
6
[kW]
4.9
[kW]
12
[W]
[kW]
4.9
[kW]
19.4
[Ω]
29
[W]
110
[kg]
9.0
9215_E
9217_E
33.9215_E
33.9217_E
1.35 x V
mains
20
40
16.5
33
37
60
250
16.5
33
51.1
66.1
11
8.5
110
110
10.5
11.0


Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

921292229217922492259226 ... Show all

Table of Contents