Configure process measurement
Effect of Temperature Damping on process measurement
Temperature Damping affects all processes and algorithms that use temperature data
from the internal sensor RTD.
Temperature compensation
Temperature compensation adjusts process measurement to compensate for the effect of
temperature on the sensor tubes.
API referral
Temperature Damping affects API referral process variables only if the transmitter is
configured to use temperature data from the sensor. If an external temperature value is
used for API referral, Temperature Damping does not affect API referral process variables.
Concentration measurement
Temperature Damping affects concentration measurement process variables only if the
transmitter is configured to use temperature data from the sensor. If an external
temperature value is used for concentration measurement, Temperature Damping does
not affect concentration measurement process variables.
4.7

Configure Pressure Measurement Unit

Display
ProLink III
Web browser
Overview
Pressure Measurement Unit controls the measurement unit used for pressure. This unit
must match the unit used by the external pressure device.
Pressure data is used for pressure compensation and for API referral. The device does not
measure pressure directly. You must set up a pressure input.
Procedure
Set Pressure Measurement Unit to the desired unit.
Default: psi
Related information
52
Menu > Configuration > Process Measurement > Pressure > Units
Device Tools > Configuration > Process Measurement > Pressure Compensation > Pres-
sure Unit
Configuration > Process Measurement > Pressure > Pressure Unit
Set up the API referral application
Set up pressure compensation
Micro Motion Model 5700 with Ethernet Transmitters