Installation Manual MMI-20039473, Rev AE October 2022 ™ Micro Motion 5700 Transmitters with Intrinsically Safe Outputs All Installation Types (Integral, 4-Wire, and 9-Wire)
Page 2
Micro Motion employees. If you fail to follow Micro Motion procedures, then Micro Motion will not accept your returned equipment. Return procedures and forms are available on our web support site at Emerson.com, or by calling the Micro Motion Customer Service department.
Power up the transmitter..................37 Chapter 7 Configuring the transmitter with Guided Setup............39 Chapter 8 Using the display controls..................41 Chapter 9 Available service port connection................43 Appendix A Wire the Micro Motion 5700 to the Micro Motion 3100 transmitter......45 Installation Manual...
Page 4
Contents Installation Manual October 2022 MMI-20039473 Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
About this document This manual provides information on planning, mounting, wiring, and initial setup of the Micro Motion 5700 transmitter. For information on full configuration, maintenance, troubleshooting, or service of the transmitter, see the . The information in this document assumes that users understand basic transmitter and sensor installation, configuration, and maintenance concepts and procedures.
Micro Motion 5700 Product Data Sheet • Micro Motion 5700 Transmitters with Intrinsically Safe Outputs: Configuration and Use Manual • Coriolis Flow Meter with Micro Motion 5700 Transmitters Safety Manual for Safety Instrumented Systems (SIS) • Modbus Interface Tool •...
For ATEX/IECEx installations, strictly adhere to the safety instructions documented in the ATEX/IECEx approvals documentation available on the product documentation DVD shipped with the product or at Emerson.com. □ Verify that you have the appropriate cable and required cable installation parts for your installation.
Typical power cable resistance at 68 °F (20.0 °C) Wire gauge Resistance 14 AWG 0.0050 Ω/ft 16 AWG 0.0080 Ω/ft 18 AWG 0.0128 Ω/ft 20 AWG 0.0204 Ω/ft 2.5 mm 0.0136 Ω/m Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
Page 9
Installation Manual Planning MMI-20039473 October 2022 Wire gauge Resistance 1.5 mm 0.0228 Ω/m 1.0 mm 0.0340 Ω/m 0.75 mm 0.0460 Ω/m 0.50 mm 0.0680 Ω/m Installation Manual...
Page 10
300 ft (91 m) VDC 20 AWG (0.518 mm²) 500 ft (152 m) VDC 18 AWG (0.823 mm²) 1,000 ft (305 m) RS-485 22 AWG (0.326 mm²) 1,000 ft (305 m) or larger Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
Installation Manual Mounting and sensor wiring MMI-20039473 October 2022 Mounting and sensor wiring Mounting and sensor wiring for integral- mount transmitters There are no separate mounting requirements for integral transmitters, and there is no need to connect wiring between the transmitter and the sensor. Mounting transmitters There is one option available for mounting 1600 remote transmitters: •...
Page 12
2. For wall-mount installations, secure the mounting bracket to the prepared surface. Figure 3-3: Wall-mounting bracket and dimensions for an aluminum transmitter A. 2.8 in (71 mm) B. 2.8 in (71 mm) Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
Page 13
Installation Manual Mounting and sensor wiring MMI-20039473 October 2022 Figure 3-4: Wall-mounting bracket and dimensions for a stainless steel transmitter A. 7.51 in (190.8 mm) B. 3.67 in (93.2 mm) 3. For aluminum transmitters, place and attach the transmitter-mounting bracket to the mounting bracket secured to the wall or instrument pole.
Page 14
Confirm that you have the necessary tools, and the instrument-pole mounting kit shipped with the transmitter. Procedure For pole-mount installations, fit the U-bolt mounting piece to the instrument pole. Figure 3-6: Pole-mounting bracket attachment for an aluminum transmitter Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
Preparation and Installation Guide. • Connect the cable to the sensor-mounted core processor or junction box as described in the sensor documentation. You can access all product documentation on the documentation DVD shipped with the product or at Emerson.com. Installation Manual...
Page 16
See the sensor installation manual for more detail. Do not connect the four-wire cable drain wires to the ground screw located inside the junction box. • Figure 3-10 for four-wire terminal connections. • Figure 3-11 for nine-wire terminal connections. Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
Page 17
Installation Manual Mounting and sensor wiring MMI-20039473 October 2022 Figure 3-10: Four-wire transmitter-to-sensor wiring connections Figure 3-11: Nine-wire transmitter-to-sensor wiring connections Note Connect the four drain wires in the nine-wire cable to the ground screw located inside the junction box. 4.
• The earth ground terminal is located inside the power wiring compartment. • The external ground screw is located on the outside of the transmitter housing below the transmitter tag. Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
Installation Manual Mounting and sensor wiring MMI-20039473 October 2022 Rotate the transmitter on the sensor (optional) In integral installations, you can rotate the transmitter on the sensor up to 360° in 45° increments. Procedure 1. Using a 4 mm hex key, loosen and remove the clamp securing the transmitter head in place.
Page 20
4. Replace the clamp in its original position and tighten the cap screw. Torque to 28 in lbf (3.16 N m) to 30 in lbf (3.39 N m). Figure 3-14: Re-attachment of the sensor clamp Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
Installation Manual Mounting and sensor wiring MMI-20039473 October 2022 Rotate the user interface on the transmitter (optional) The user interface on the transmitter electronics module can be rotated 90°, 180°, or 270° from the original position. Figure 3-15: Display components A.
Figure 3-16: Removal of the clamp 2. Gently rotate the junction box to the desired position. You can rotate the junction box plus or minus 180° to any position. Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
Page 23
Installation Manual Mounting and sensor wiring MMI-20039473 October 2022 Figure 3-17: Rotate the transmitter on the junction box 3. Gently set the junction box into its new position, confirming that the position is locked. 4. Replace the clamp in its original position and tighten the cap screw. Torque to 28 in lbf (3.16 N m) to 30 in lbf (3.39 N m).
Page 24
Mounting and sensor wiring Installation Manual October 2022 MMI-20039473 Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
If you are installing the transmitter in a hazardous area, refer to Micro Motion approval instructions shipped with the product or available from the Emerson website. Improper installation in a hazardous area can cause an explosion resulting in injury or death.
This includes all sensor resistance and wire resistance. Channel A mA HART terminal requirements Use the following chart to determine the required supply voltage for Channel A based on loop resistance. Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
Page 27
Installation Manual Wiring the channels MMI-20039473 October 2022 Figure 4-1: Channel A mA/HART supply voltage and loop resistance A. Total loop resistance R (including barrier) B. Supply voltage VDC (volts) C. Operating region with HART D. Operating region without HART (includes the C range) Channel B or C terminal requirements Use the following chart to determine the required supply voltage for Channel B or C based on loop resistance.
Blue line = Maximum Red line = Minimum A. External resistor R load B. Supply voltage VDC (volts) C. Operating region Note Rmax = (Vsupply - 6) / 0.0025 Rmin = 100Ω Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
Installation Manual Wiring the channels MMI-20039473 October 2022 Figure 4-4: Output high and low voltages A. Output voltage (V) B. Load resistance (ohm) ﹣ 1.8V) * RL / (1200 + RL) C. High voltage ≈ (Vsupply D. Low voltage ≈ 0.0008*RL Minimum resistance = 100Ω...
Wire the mA/HART Output in explosion-proof, intrinsically safe, or nonhazardous installations. WARNING Meter installation and wiring should be performed only by suitably-trained personnel using the appropriate government and corporate safety standards. Procedure Wire to the appropriate output terminal and pins. Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
Installation Manual Wiring the channels MMI-20039473 October 2022 Figure 4-7: Channel A mA/HART output wiring A. Hazardous area B. Non-hazardous area C. mA/HART output D. 250–600 Ω resistance E. 24V nominal F. HART device Wire the Channel B and C mA Output Wire the mA Output in explosion-proof, intrinsically safe, or nonhazardous installations.
E. 24V nominal F. Input device Wire the mA/SIL output Refer to the Coriolis Flow Meter with Micro Motion 5700 Transmitters Safety Manual for Safety Instrumented Systems (SIS) for additional information regarding installation and commissioning that complies with SIS requirements.
Installation Manual Wiring the channels MMI-20039473 October 2022 Figure 4-9: mA/HART multidrop wiring A. Input Device 1 B. Input Device 2 C. Input Device 3 D. Meter (mA+/HART output) E. Hazardous area F. Non-hazardous area G. DIN rail H. 250 Ω resistance I.
Page 34
Installation Manual October 2022 MMI-20039473 Figure 4-10: Frequency Output or Discrete Output wiring A. Hazardous area B. Non-hazardous area C. Frequency Output D. 250–600 Ω resistance E. 24V nominal F. Input device Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
Installation Manual Wiring the power supply MMI-20039473 October 2022 Wiring the power supply You can install a user-supplied switch in the power supply line. Important For compliance with the Low Voltage Directive 2014/35/EU (European installations), verify that the transmitter is located in close proximity to a switch. Procedure 1.
Page 36
Wiring the power supply Installation Manual October 2022 MMI-20039473 Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
Installation Manual Power up the transmitter MMI-20039473 October 2022 Power up the transmitter The transmitter must be powered up for all configuration and commissioning tasks or for process measurement. Procedure WARNING If the transmitter is in a hazardous area, do not remove the housing cover while the transmitter is powered up.
Page 38
Power up the transmitter Installation Manual October 2022 MMI-20039473 Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
Installation Manual Configuring the transmitter with Guided Setup MMI-20039473 October 2022 Configuring the transmitter with Guided Setup At initial start-up of the transmitter, the guided configuration screen appears on the transmitter display. This tool guides you through basic configuration of the transmitter. The guided setup allows you to upload configuration files, set the transmitter display options, configure channels, and review sensor calibration data.
Page 40
Configuring the transmitter with Guided Setup Installation Manual October 2022 MMI-20039473 Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
Installation Manual Using the display controls MMI-20039473 October 2022 Using the display controls The transmitter display interface includes a display (LCD panel) and four optical switches – left, up, down, and right arrow keys – used to access the display menus and navigate the display screens.
Page 42
Using the display controls Installation Manual October 2022 MMI-20039473 Figure 8-2: Example 1: Active arrow indicators on the transmitter display Figure 8-3: Example 2: Active arrow indicators on the transmitter display Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
Installation Manual Available service port connection MMI-20039473 October 2022 Available service port connection Use the service port connection to download or upload data from/to the transmitter. To access the service port, you can use commonly-available USB hardware, such as a USB drive, or USB cable.
Page 44
Available service port connection Installation Manual October 2022 MMI-20039473 Micro Motion 5700 transmitters with Intrinsically Safe Outputs...
Installation Manual Wire the Micro Motion 5700 to the Micro Motion 3100 transmitter MMI-20039473 October 2022 Wire the Micro Motion 5700 to the Micro Motion 3100 transmitter Prerequisites • Set up the transmitter channel configuration to DO before wiring. •...