Table 7-2:
Options for alerts and conditions
Alert
Name
Drive Over-Range
[102] Drive Overrange
Default severi-
ty: Mainte-
nance
Severity config-
urable: Yes
Fault Timeout
applicable: Yes
Process Aberration
[105] Two-Phase Flow
Default severi-
ty: Out of Spec-
ulation
[138] TBR Active
Severity config-
urable: Yes
Fault Timeout
applicable: Yes
[121] Extrapolation Alert (Concentration)
[116] Temperature Overrange (API referral)
[117] Density Overrange (API referral)
[123] Pressure Overrange (API referral)
Moderate Two-Phase Flow
Severe Two-Phase Flow
Batch Time Out
Event Active
Enhanced Event 1 Active
Configuration and Use Manual
(continued)
Conditions
Configure device options and preferences
Description
The drive power (current/
voltage) is at its maxi-
mum.
The line density is outside
the user-defined two-
phase flow limits.
Drive gain is above the
configured threshold and
transient bubble remedia-
tion is active.
The line density or line
temperature is outside
the range of the concen-
tration matrix plus the
configured extrapolation
limit.
The line temperature is
outside the range of the
API table.
The line density is outside
the range of the API table.
The line pressure is out-
side the range of the API
table.
The transmitter has de-
tected moderate two-
phase flow.
The transmitter has de-
tected severe two-phase
flow.
The batch exceeded Maxi-
mum Batch Time, and
was ended before the tar-
get was reached.
The conditions assigned
to Enhanced Event 1 are
present.
Ignora-
ble
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
113