Table Of Contents - Emerson Micro Motion 5700 Configuration And Use Manual

Model 5700 with ethernet
Hide thumbs Also See for Micro Motion 5700:
Table of Contents

Advertisement

Contents
Chapter 1
Before you begin ............................................................................................................. 3
1.1
About this manual ......................................................................................................................... 3
1.2
Communication methods ..............................................................................................................3
1.3
Additional documentation and resources ...................................................................................... 4
Quick start .......................................................................................................................5
2.1
Power up the transmitter ...............................................................................................................5
2.2
Check meter status ........................................................................................................................6
2.3
Commissioning wizards .................................................................................................................6
2.4
Make a startup connection to the transmitter ................................................................................6
2.5
Set the transmitter clock ............................................................................................................... 7
2.6
View the licensed features ............................................................................................................. 8
2.7
Set informational parameters ........................................................................................................ 8
2.8
Characterize the meter (if required) ...............................................................................................9
2.8.1
2.8.2
2.8.3
2.9
Verify mass flow measurement ....................................................................................................13
2.10
Verify the zero ............................................................................................................................. 13
Chapter 3
Introduction to configuration and commissioning ......................................................... 17
3.1
Security and write protection ...................................................................................................... 17
3.1.1
3.1.2
3.1.3
3.1.4
3.2
Work with configuration files .......................................................................................................21
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
3.2.6
Chapter 4
Configure process measurement ................................................................................... 29
4.1
Configure Sensor Flow Direction Arrow .......................................................................................29
4.2
Configure mass flow measurement ............................................................................................. 31
4.2.1
4.2.2
4.2.3
4.3
Configure volume flow measurement for liquid applications ....................................................... 36
Configuration and Use Manual
Sample sensor tags ....................................................................................................... 11
Flow calibration parameters (FCF, FT) ........................................................................... 11
Density calibration parameters (D1, D2, K1, K2, FD, DT, TC) ......................................... 12
Lock or unlock the transmitter ...................................................................................... 17
Enable or disable the service port ..................................................................................19
Enable or disable software write-protection .................................................................. 20
Configure security for the display ..................................................................................20
Save a configuration file using the display ..................................................................... 21
Save a configuration file using ProLink III ...................................................................... 23
Load a configuration file using the display .....................................................................24
Load a configuration file using ProLink III ......................................................................25
Restore the factory configuration ................................................................................. 27
Replicate a transmitter configuration ............................................................................27
Configure Mass Flow Measurement Unit ...................................................................... 31
Configure Flow Damping ..............................................................................................33
Configure Mass Flow Cutoff ..........................................................................................34
Contents
i

Advertisement

Table of Contents
loading

Table of Contents