Software history (NAMUR recommendation NE53)
Updated confidence settings defaults in the Advanced Phase Measurement
application
The following table contains the updated confidence settings for the APM application that
were corrected in software v1.20 of the Model 5700 Ethernet transmitters.
Name
Confidence DG
Threshold 1
Confidence DG
Threshold 2
Confidence GVF
Threshold 1
276
Modbus
Register
Description
3929
Configuration
(Service, FF:
In Service)
3931
Configuration
(Service, FF:
In Service)
3933
Configuration
(Service,
FF: In Service)
Micro Motion Model 5700 with Ethernet Transmitters
Default
Unit of Measure
value
FLOAT (units of
1000
extended drive gain)
(50 in earlier firmware)
FLOAT (units of
(1.0 - 1000)
extended drive gain)
FLOAT
1000
(units of %)
(150 in earlier firmware)