Table 4-2:
Options for Volume Flow Measurement Unit for liquid applications
Unit description
Special unit
(1) Unit based on oil barrels (42 U.S. gallons).
(2) Unit based on U.S. beer barrels (31 U.S. gallons).
Define a special measurement unit for volume flow
Display
ProLink III
Web browser
Procedure
1.
2.
3.
4.
5.
6.
The special measurement unit is stored in the transmitter. You can configure the
transmitter to use the special measurement unit at any time.
Example: Defining a special measurement unit for volume flow
You want to measure volume flow in pints per second (pints/sec).
1.
2.
Configuration and Use Manual
Display
SPECIAL
Menu > Configuration > Process Measurement > Flow Variables > Volume Flow Settings >
Units > SPECIAL
Device Tools > Configuration > Process Measurement > Flow > Volume Flow Rate Unit >
Special
Configuration > Process Measurement > Flow Variables > Volume Flow Rate Unit > Spe-
cial
Specify Base Volume Unit.
Base Volume Unit is the existing volume unit that the special unit will be based on.
Specify Base Time Unit.
Base Time Unit is the existing time unit that the special unit will be based on.
Calculate Volume Flow Conversion Factor as follows:
a. x base units = y special units
b. Volume Flow Conversion Factor = x ÷ y
Enter Volume Flow Conversion Factor.
The original volume flow rate value is divided by this conversion factor.
Set Volume Flow Label to the name you want to use for the volume flow unit.
Set Volume Total Label to the name you want to use for the volume total and
volume inventory unit.
Set Base Volume Unit to Gallons (gal).
Set Base Time Unit to Seconds (sec).