Example: Extrapolation alerts in action
If Extrapolation Limit is set to 5%, High Limit (Temp) is enabled, and the active matrix is
built for a temperature range of 40 °F to 80 °F, a high-temperature extrapolation alert will
be posted if line temperature goes above 82 °F.
Select the active concentration matrix using ProLink III
You must select the concentration matrix to be used for measurement. Although the
transmitter can store up to six concentration matrices, only one matrix can be used for
measurement at any one time.
1.
2.
5.2.4

Set up concentration measurement using a web browser

This section guides you through the tasks required to set up, configure, and implement
concentration measurement.
Configuration and Use Manual
Choose Device Tools > Configuration > Process Measurement > Concentration
Measurement.
The Concentration Measurement window is displayed. It is organized into steps that
allow you to perform several different setup and configuration tasks. For this task,
you will not use all the steps.
Scroll to Step 2, set Matrix Being Configured to the matrix you want to modify, and
click Change Matrix.
Scroll to Step 4.
Set Extrapolation Alert Limit to the point, in percent, at which an extrapolation alert
will be posted.
Enable or disable the high and low limit alerts for temperature and density, as
desired, and click Apply.
Choose Device Tools > Configuration > Process Measurement > Concentration
Measurement.
Scroll to Step 2, set Active Matrix to the matrix you want to use and click Change
Matrix.
Enable the concentration measurement application using a web browser
Set reference temperature values for specific gravity using a web browser
Provide temperature data for concentration measurement using a web browser
Modify matrix names and labels using the a web browser
Modify extrapolation alerts for concentration measurement using a web browser
Select the active concentration matrix using a web browser