Set Up Concentration Measurement Using The Display - Emerson Micro Motion 5700 Configuration And Use Manual

Model 5700 with ethernet
Hide thumbs Also See for Micro Motion 5700:
Table of Contents

Advertisement

Configure process measurement applications
5.2.2

Set up concentration measurement using the display

This section guides you through most of the tasks related to setting up and implementing
the concentration measurement application.
Restriction
This section does not cover building a concentration matrix. See Micro Motion Enhanced Density
Application: Theory, Configuration, and Use for detailed information on building a matrix.
Enable the concentration measurement application using
the display
The concentration measurement application must be enabled before you can perform any
setup. If the concentration measurement application was enabled at the factory, you do
not need to enable it now.
Prerequisites
The concentration measurement application must be licensed on your transmitter.
Procedure
1.
2.
3.
4.
5.
6.
66
Enable the concentration measurement application using the display
Load a concentration matrix from a USB drive using the display
Load a concentration matrix from the SD card using the display
Set up temperature data for concentration measurement using the display
Modify matrix names and labels using the display
Modify extrapolation alerts for concentration measurement using the display
Select the active concentration matrix using the display
Choose Menu > Configuration > Process Measurement.
Choose Flow Variables > Volume Flow Settings and ensure that Flow Type is set to
Liquid.
Return to the Process Measurement menu.
If the API referral application is displayed in the menu, choose API Referral and
ensure that Enabled/Disabled is set to Disabled.
The concentration measurement application and the API referral application cannot
be enabled simultaneously.
If the advanced phase measurement application is displayed in the menu, choose
Advanced Phase Measurement > Application Setup and ensure that Enabled/
Disabled is set to Disabled.
The concentration measurement application and the advanced phase measurement
application cannot be enabled simultaneously.
Enable concentration measurement.
a. Choose Menu > Configuration > Process Measurement > Concentration
Measurement.
Micro Motion Model 5700 with Ethernet Transmitters