Appendix D
Concentration measurement matrices,
derived variables, and process variables
Topics covered in this appendix:
D.1
Standard matrices for the concentration
measurement application
The standard concentration matrices available from Micro Motion are applicable for a
variety of process fluids. These matrices are included in the ProLink III installation.
Tip
If the standard matrices are not appropriate for your application, you can build a custom matrix or
purchase a custom matrix from Micro Motion.
Matrix name
Description
Deg Balling
Matrix represents percent extract, by
mass, in solution, based on °Balling.
For example, if a wort is 10 °Balling
and the extract in solution is 100% su-
crose, the extract is 10% of the total
mass.
Deg Brix
Matrix represents a hydrometer scale
for sucrose solutions that indicates the
percent by mass of sucrose in solution
at a given temperature. For example,
40 kg of sucrose mixed with 60 kg of
water results in a 40 °Brix solution.
Deg Plato
Matrix represents percent extract, by
mass, in solution, based on °Plato. For
example, if a wort is 10 °Plato and the
extract in solution is 100% sucrose, the
extract is 10% of the total mass.
Configuration and Use Manual
Concentration measurement matrices, derived variables, and process variables

Standard matrices for the concentration measurement application

Derived variables and calculated process variables
Temperature
Density unit
unit
3
g/cm
°F
3
°C
g/cm
3
g/cm
°F
Derived variable
Mass Concentration
(Density)
Mass Concentration
(Density)
Mass Concentration
(Density)