15.1 List of Parameters
15.1.2 List of Parameters
Parameter
No.
Pn561
Pn581
Pn582
Pn583
Pn584
Pn585
Pn586
Pn587
Pn600
Pn601
Pn603
Pn604
Pn61A
Pn61B
*6
Pn61C
*6
Pn61D
*6
Pn621 to
Pn628
PnB01
15-22
Name
Overshoot Detection
2
Level
2
Zero Speed Level
Reserved parameter
2
(Do not change.)
Brake Reference Out-
2
put Speed Level
Speed Limit Level at
2
Servo ON
Program Jogging Move-
2
ment Speed
Motor Running Cooling
2
Ratio
Reserved parameter
2
(Do not change.)
Regenerative Resistor
2
*2
Capacity
Dynamic Brake Resis-
2
tor Allowable Energy
Consumption
Regenerative Resis-
2
tance
Dynamic Brake Resis-
2
tance
Overheat Protection
2
Selections
n.  X
Overheat Protection Selection
0
Disable overheat protection.
1
Use overheat protection in the Yaskawa Linear Servomotor.
Monitor a negative voltage input from a sensor attached to the machine and
2
use overheat protection.
Monitor a positive voltage input from a sensor attached to the machine and
3
use overheat protection.
n.  X 
Reserved parameter (Do not change.)
n.  X 
Reserved parameter (Do not change.)
n.X 
Reserved parameter (Do not change.)
2
Overheat Alarm Level
2
Overheat Warning Level
Overheat Alarm Filter
2
Time
Reserved parameters
(Do not change.)
2
Origin Return Direction
0000h
Forward
0001h
Reverse
Setting
Setting
Default
Range
Unit
Setting
0 to 100
1%
100
1 to 10,000
1 mm/s
20
10
0 to 10,000
1 mm/s
10
0 to 10,000
1 mm/s
10000
1 to 10,000
1 mm/s
50
1%/
0 to 100
Max.
0
speed
0000h
Depends on
10 W
0
*3
model.
0 to 65,535
10 J
0
0 to 65,535
10 mΩ
0
0 to 65,535
10 mΩ
0
0000h to
0000h
0003h
0 to 500
0.01 V
250
0 to 100
1%
100
0 to 65,535
1 s
0
0000h and
0001h
0001h
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
Immedi-
All
Setup
ately
Immedi-
Linear
Setup
ately
Linear
Immedi-
Linear
Setup
ately
Immedi-
Linear
Setup
ately
Immedi-
Linear
Setup
ately
Immedi-
Linear
Setup
ately
Linear
Immedi-
All
Setup
ately
After
All
Setup
restart
Immedi-
All
Setup
ately
After
All
Setup
restart
After
Linear
Setup
restart
*5
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
All
Immedi-
All
Setup
ately
Continued on next page.
Refer-
ence
page
8-30,
page
8-40
page
1-8
page
5-30
page
8-9
page
7-13
page
5-52
*4
page
5-52
*4
page
6-35
page
6-36
page
6-36
page
6-36
page
12-4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-oca04aSgdv-oca05a

Table of Contents