16.3 DeviceNet Attributes
16.3.11 SERVOPACK Parameter Object
No.
68
71
73
74
75
76
79
80
81
82
83
88
89
90
92
93
94
95
97
98
99
104
16-20
Access
Name
Tuning-less
Get/Set
Function
Related Switch
Multi-turn Limit
Get/Set
Setting
Number of
Get/Set
External Scale
Pitch
Electronic Gear
Get/Set
Ratio
(Numerator)
Electronic Gear
Get/Set
Ratio
(Denominator)
Encoder Out-
Get/Set
put Pulses
Fully-closed
Get/Set
Control Selec-
tion Switch
Position Con-
Get/Set
trol Expanded
Function Switch
Backlash Com-
Get/Set
pensation Value
Backlash Com-
Get/Set
pensation Time
Constant
Encoder Out-
Get/Set
put Resolution
Get/Set
JOG Speed
Soft Start
Get/Set
Acceleration
Time
Soft Start
Get/Set
Deceleration
Time
Vibration
Get/Set
Detection
Switch
Vibration
Get/Set
Detection
Sensibility
Vibration
Get/Set
Detection Level
Moment of Iner-
Get/Set
tia Calculating
Start Level
Torque Refer-
Get/Set
ence Filter Time
Constant
Forward Torque
Get/Set
Limit
Reverse Torque
Get/Set
Limit
Torque Related
Get/Set
Function
Switch
Data Type
Sets the tuning-less function-related
UINT
selections.
Sets the multiturn limit setting.
UINT
Unit: rev
Sets the number of external encoder
UDINT
pitches.
UDINT
Sets the electronic gear ratio numerator.
UDINT
Sets the electronic gear ratio denominator.
Sets number of encoder output pulses 1.
UDINT
Unit: P/Rev
UINT
Sets the fully-closed control selections.
Sets the position control expansion func-
UINT
tion selections.
Sets the backlash compensation.
DINT
Unit: 0.1 reference units
Sets the backlash compensation time
UINT
constant.
Unit: 0.01 ms
Sets the encoder output resolution
UINT
(edges/pitch).
Sets the jogging speed.
UINT
-1
Unit: min
Sets the soft start acceleration time.
UINT
Unit: ms
Sets the soft start deceleration time.
UINT
Unit: ms
UINT
Sets the vibration detection selections.
Sets the vibration detection sensitivity.
UINT
Unit: %
Sets the vibration detection level.
UINT
-1
Unit: min
Sets the moment of inertia calculation
UINT
start level.
Unit: %
Sets the first stage first torque reference
UINT
filter time constant.
Unit: 0.01 ms
Sets the forward torque limit.
UINT
Unit: %
Sets the reverse torque limit.
UINT
Unit: %
Sets the torque-related function selec-
UINT
tions.
Continued from previous page.
Description
Continued on next page.
Value
0x0000 to
0x2411
0 to 65,535
4 to
1,048,576
1 to
1,073,741,82
4
1 to
1,073,741,82
4
16 to Upper
limit of
encoder
0x0000 to
0x1003
0 or 1
-500,000 to
500,000
0 to 65,535
1 to 4,096
0 to 10,000
0 to 10,000
0 to 10,000
0x0000 to
0x0002
50 to 500
0 to 5,000
0 to 20,000
0 to 65,535
0 to 800
0 to 800
0x0000 to
0x1111