The brake operates when either of the following conditions is satisfied:
• When the Motor Speed Goes below the Level Set in Pn507 for a Rotary Servomotor or in
Pn583 for a Linear Servomotor after the Power Supply to the Motor Is Stopped
/S-ON input, alarm,
ON
or power OFF
Motor speed
Power
Motor power status
supplied.
/BK signal
ON (Brake released.)
• When the Time Set In Pn508 Elapses after the Power Supply to the Motor Is Stopped
ON
/S-ON input, alarm,
or power OFF
Motor speed
Motor power status
Power
supplied.
ON (Brake released.)
/BK signal
The Servomotor will be limited to its maximum speed even if the brake reference output speed
level (Rotary Servomotor: Pn507, Linear Servomotor: Pn583) is higher than the maximum speed.
Important
5.11.4 Output Timing of /BK (Brake) Signal When the Servomotor Is Operating
OFF
Rotary Servomotor: Pn507
Linear Servomotor: Pn583
Motor stopped with dynamic
brake or by coasting
(Pn001 = n.X)
Power not supplied.
OFF (Brake applied.)
Pn508
OFF
Rotary Servomotor: Pn507
Linear Servomotor: Pn583
Motor stopped with dynamic
brake or by coasting
(Pn001 = n.
Power not supplied.
OFF (Brake
applied.)
Pn508
5.11 Holding Brake
X)