YASKAWA SGD7S Product Manual page 549

E-7-series
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

16.3 DeviceNet Attributes
16.3.5 Connection Objects
No.
9
12
13
14
15
16
 Attributes for Instance 2: Polled I/O
No.
1
2
3
4
5
6
7
8
9
12
13
14
15
16
16-10
Access
Name
Expected_
Get/Set
Packet_Rate
Watchdog_
Get
Timeout_
Action
Produced_
Get
Connection_
Path_Length
Produced_
Get
Connection_
Path
Consumed_
Get
Connection_
Path_Length
Consumed_
Get
Connection_
Path
Access
Name
Get
State
Get
Instance_Type
TransportClass
Get
_Trigger
Produced_
Get
Connection_ID
Consumed_
Get
Connection_ID
Initial_Comm_
Get
Characteristics
Produced_
Get
Connection_
Size
Consumed_
Get
Connection_
Size
Expected_
Get/Set
Packet_Rate
Watchdog_
Get
Timeout_
Action
Produced_
Get
Connection_
Path_Length
Produced_
Get
Connection_
Path
Consumed_
Get
Connection_
Path_Length
Consumed_
Get
Connection_
Path
Data Type
UINT
Defines the timing for this connection.
USINT
Defines how to handle timeouts.
Gives the number of bytes in the Produced
UINT
Connection Path attribute.
USINT
Specifies the application object where data
Array
will be sent by this connection object.
Gives the number of bytes in the Con-
UINT
sumed Connection Path attribute.
Specifies the application object that will
USINT
receive the data that was received by this
Array
connection object.
Data Type
USINT
Gives the state of the object.
USINT
Gives the message connection.
Byte
Defines the behavior of the connection.
Placed in the CAN ID field when the con-
UINT
nection sends a message.
Gives the value of the CAN ID field that
UINT
indicates the message to receive.
Defines the message group where mes-
USINT
sage transmission and reception process-
ing for this connection occur.
Gives the maximum number of bytes sent
UINT
through this connection.
Gives the maximum number of bytes
UINT
received through this connection.
UINT
Defines the timing for this connection.
USINT
Defines how to handle timeouts.
Gives the number of bytes in the Produced
UINT
Connection Path attribute.
USINT
Specifies the application object where
Array
data will be sent by this connection object.
Gives the number of bytes in the Con-
UINT
sumed Connection Path attribute.
Specifies the application object that will
USINT
receive the data that was received by this
Array
connection object.
Continued from previous page.
Description
Description
Value
0x03
0x0000
0x0000
Value
0x01
0x83
0x01
0x0008
0x0008
0x01
0x0006
20_04_24_0
1_30_03
0x0006
20_04_24_0
2_30_03

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-oca04aSgdv-oca05a