YASKAWA SGD7S Product Manual page 561

E-7-series
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

16.3 DeviceNet Attributes
16.3.11 SERVOPACK Parameter Object
No.
140
141
142
143
144
145
147
148
149
150
151
152
153
154
155
156
157
158
159
 Services
Service Code
0x0E
0x10
16-22
Access
Name
Excessive Posi-
tion Error Alarm
Get/Set
Level at Servo
ON
Excessive Posi-
tion Error Warn-
Get/Set
ing Level at
Servo ON
Speed Limit
Get/Set
Level at Servo
ON
Multiplier per
Get/Set
One Fully-
closed Rotation
Overload Warn-
Get/Set
ing Level
Derating of
Base Current at
Get/Set
Detecting Over-
load of Motor
Program JOG
Get/Set
Operation
Related Switch
Program JOG
Get/Set
Movement Dis-
tance
Program JOG
Get/Set
Movement
Speed
Program JOG
Acceleration /
Get/Set
Deceleration
Time
Program JOG
Get/Set
Waiting Time
Number of
Times of Pro-
Get/Set
gram JOG
Movement
Analog Monitor
Get/Set
1 Offset Voltage
Analog Monitor
Get/Set
2 Offset Voltage
Analog Monitor
Get/Set
1 Magnification
Analog Monitor
Get/Set
2 Magnification
Remained
Get/Set
Vibration
Detection Width
Overshoot
Get/Set
Detection Level
Regenerative
Get/Set
Resistor
Capacity
Service
Get_Attribute_Single
Set_Attribute_Single
Data Type
Sets the position deviation overflow alarm
UDINT
level when the servo is turned ON.
Unit: Reference units
Sets the position deviation overflow warn-
UINT
ing level when the servo is turned ON.
Unit: %
Sets the speed limit level when the servo
is turned ON.
UINT
-1
Unit: min
Sets the multiplier per fully-closed rota-
UINT
tion.
Unit: %
Sets the overload warning level.
UINT
Unit: %
Sets the base current derating at motor
UINT
overload detection.
Unit: %
Sets the program jogging-related selec-
UINT
tions.
Sets the program jogging travel distance.
UINT
Unit: Reference units
Sets the program jogging movement
speed.
UINT
-1
Unit: min
Sets the program jogging acceleration/
UINT
deceleration time.
Unit: ms
Sets the program jogging waiting time.
UINT
Unit: ms
Sets the number of program jogging
UINT
movements.
Unit: Number of movements
Sets the analog monitor 1 offset voltage.
INT
Unit: 0.1 V
Sets the analog monitor 2 offset voltage.
INT
Unit: 0.1 V
Sets the analog monitor 1 magnification.
INT
Unit: 0.01x
Sets the analog monitor 2 magnification.
INT
Unit: 0.01x
Sets the residual vibration detection
UINT
width.
Unit: 0.1%
Sets the overshoot detection level.
UINT
Unit: %
Sets the regenerative resistor capacity.
UINT
Unit: 10 W
Returns the value of the specified attribute.
Changes the value of the specified attribute.
Continued from previous page.
Description
Description
Value
1 to
1,073,741,823
10 to 100
0 to 10,000
0 to 100
1 to 100
10 to 100
0x0000 to
0x0005
1 to
1,073,741,824
1 to 10,000
2 to 10,000
0 to 10,000
0 to 1,000
-10,000 to
10,000
-10,000 to
10,000
-10,000 to
10,000
-10,000 to
10,000
1 to 3,000
0 to 100
0 to Upper limit
of SERVO-
PACK capacity

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-oca04aSgdv-oca05a

Table of Contents