YASKAWA SGD7S Product Manual page 480

E-7-series
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

Alarm Number:
Possible Cause
Alarm Name
There is a faulty con-
nection between the
SERVOPACK and the
Safety Option Module.
The Safety Option
A.E71:
Module was discon-
Safety Option
nected.
Module Detec-
tion Failure
A failure occurred in
the Command Option
Module.
A failure occurred in
the SERVOPACK.
There is a faulty con-
nection between the
SERVOPACK and the
Feedback Option
Module.
A.E72:
The Feedback Option
Feedback Option
Module was discon-
Module Detec-
nected.
tion Failure
A failure occurred in
the Feedback Option
Module.
A failure occurred in
the SERVOPACK.
A failure occurred in
the Command Option
A.E73:
Module.
Unsupported
Command Option
An unsupported Com-
Module
mand Option Module
was connected.
A failure occurred in
the Safety Option
A.E74:
Module.
Unsupported
Safety Option
An unsupported
Module
Safety Option Module
was connected.
A failure occurred in
the Feedback Option
*2
Module.
A.E75
:
Unsupported
An unsupported
Feedback Option
Feedback Option
Module
Module was con-
nected.
A.E80:
The Command Option
Command Option
Module was replaced
Module Detec-
with a different model.
tion Inconsistency
Confirmation
Check the connection
between the SERVO-
Correctly connect the
PACK and the Safety
Safety Option Module.
Option Module.
Reset the Option Module
configuration error and
turn the power supply to
the SERVOPACK OFF and
ON again.
Replace the Safety Option
Module.
Replace the SERVO-
PACK.
Check the connection
between the SERVO-
Correctly connect the
PACK and the Feed-
Feedback Option Module.
back Option Module.
Reset the Option Module
configuration error and
turn the power supply to
the SERVOPACK OFF and
ON again.
Replace the Feedback
Option Module.
Replace the SERVO-
PACK.
Replace the Command
Option Module.
Connect a supported
Command Option Mod-
ule.
Replace the Safety Option
Module.
Connect a supported
Safety Option Module.
Replace the Feedback
Option Module.
Refer to the catalog for
the connected Feed-
Connect a supported
back Option Module or
Feedback Option Module.
the SERVOPACK man-
ual.
Reset the Option Module
configuration error and
turn the power supply to
the SERVOPACK OFF and
ON again.
14.2 Alarm Displays
14.2.2 Troubleshooting Alarms
Continued from previous page.
Correction
Reference
page 14-46
page 14-46
Continued on next page.