Wiring Reactors For Harmonic Suppression - YASKAWA SGD7S Product Manual

E-7-series
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

4.3 Wiring the Power Supply to the SERVOPACK

4.3.6 Wiring Reactors for Harmonic Suppression

4.3.6

Wiring Reactors for Harmonic Suppression

You can connect a reactor for harmonic suppression to the SERVOPACK when power supply
harmonic suppression is required. Refer to the following manual for details on reactors for har-
monic suppression.
Σ-7-Series Peripheral Device Selection Manual (Manual No.: SIEP S800001 32)
Refer to the following figures to connect reactors.
Note: 1. Connection terminals
2. Reactors are optional products. (Purchase them separately.)
3. You cannot connect a DC Reactor to a SERVOPACK with a single-phase, 100-VAC power supply input.
4-24
SERVOPACK with Three-Phase,
200-VAC Power Supply Input
SERVOPACK
DC Reactors
1
2
1 and
Remove the lead wire and connect a DC Reactor.
SERVOPACK with Single-Phase,
100-VAC Power Supply Input
Power
Supply
2 for a DC Reactor are connected when the SERVOPACK is shipped.
SERVOPACK
AC Reactors