Parameter
Default
No.
Setting
PnB2B
4000000
PnB40
4
PnB41
0
PnB42
25
PnB50
5
PnB51
0
PnB54
400000
PnB55
0
PnB59
0000h
PnBA3
0000h
PnBA4
00A3h
PnBA5
0000h
PnBA7
0000h
PnBA9
10000
PnBAA
4000000
PnBAB
4000000
*
The enable timing depends on the digit that is changed. Refer to the following section for details.
15.1 List of Parameters on page 15-2
15.2 Parameter Recording Table
Continued from previous page.
Name
Deceleration Rate
Time Constant for Expo-
nential Acceleration/Decel-
eration
Exponential Acceleration/
Deceleration Bias Speed
Average Movement Time
Filter Time Constant
Positioning Completed
Width
Positioning Completion
Timeout Time
Positioning Approach
Speed
End Position
Approach Mode
Input Signal Logic Setting
Input Signal Setting
Action Definition Setting
Initialization Setting
Reserved parameter
Reserved parameter
Reserved parameter
When
Enabled
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
Immediately
After restart
After restart
15
15-33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-oca04aSgdv-oca05a