YASKAWA SGD7S Product Manual page 470

E-7-series
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

Alarm Number:
Possible Cause
Alarm Name
A.bF3:
A failure occurred in
the SERVOPACK.
System Alarm 3
A.bF4:
A failure occurred in
System Alarm 4
the SERVOPACK.
A.bF5:
A failure occurred in
the SERVOPACK.
System Alarm 5
A.bF6:
A failure occurred in
the SERVOPACK.
System Alarm 6
A.bF7:
A failure occurred in
the SERVOPACK.
System Alarm 7
A.bF8:
A failure occurred in
the SERVOPACK.
System Alarm 8
The order of phases
U, V, and W in the
motor wiring is not
correct.
There is an error in the
setting of Pn080 =
n.X (Motor
Phase Selection).
A.C10:
Servomotor Out
of Control
(Detected when
A failure occurred in
the servo is
the encoder.
turned ON.)
A failure occurred in
the SERVOPACK.
Confirmation
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Check the Servomotor
Make sure that the Servo-
wiring.
motor is correctly wired.
Check the setting of
Set Pn080 = n.X to
Pn080 = n.X.
an appropriate value.
If the motor wiring is cor-
rect and an alarm still
occurs after turning the
power supply OFF and
ON again, the Servomotor
or linear encoder may be
faulty. Replace the Servo-
motor or linear encoder.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
14.2 Alarm Displays
14.2.2 Troubleshooting Alarms
Continued from previous page.
Correction
Reference
page 5-22
Continued on next page.
14
14-29

Advertisement