YASKAWA SGD7S Product Manual page 558

E-7-series
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

No.
Access
Name
Model Follow-
50
Get/Set
ing Control
Gain
Model Follow-
ing Control
51
Get/Set
Gain Compen-
sation
Model Follow-
ing Control Bias
52
Get/Set
(Forward Direc-
tion)
Model Follow-
ing Control Bias
53
Get/Set
(Reverse Direc-
tion)
Vibration Sup-
54
Get/Set
pression 1 Fre-
quency A
Vibration Sup-
55
Get/Set
pression 1 Fre-
quency B
Model Follow-
ing Control
56
Get/Set
Speed Feedfor-
ward
Compensation
2nd Model Fol-
57
Get/Set
lowing Control
Gain
2nd Model Fol-
lowing Control
58
Get/Set
Gain Compen-
sation
Vibration Sup-
59
Get/Set
pression 2 Fre-
quency
Vibration Sup-
60
Get/Set
pression 2
Compensation
Anti-Reso-
62
Get/Set
nance Control
Related Switch
Anti-Reso-
63
Get/Set
nance Fre-
quency
Anti-Reso-
64
Get/Set
nance Gain
Compensation
Anti-Reso-
65
Get/Set
nance Damp-
ing Gain
Anti-Reso-
nance Filter
66
Get/Set
Time Constant
1 Compensa-
tion
Anti-Reso-
nance Filter
67
Get/Set
Time Constant
2 Compensa-
tion
Data Type
Sets the model following control gain.
UINT
Unit: 0.1/s
Sets the model following control gain cor-
UINT
rection.
Unit: 0.1%
Sets the model following control bias in
UINT
the forward direction.
Unit: 0.1%
Sets the model following control bias in
UINT
the reverse direction.
Unit: 0.1%
Sets vibration suppression 1 frequency A.
UINT
Unit: 0.1 Hz
Sets vibration suppression 1 frequency B.
UINT
Unit: 0.1 Hz
Sets the model following control speed
UINT
feedforward compensation.
Unit: 0.1%
Sets the second model following control
UINT
gain.
Unit: 0.1/s
Sets the second model following gain
UINT
control correction.
Unit: 0.1%
Sets the vibration suppression 2 fre-
UINT
quency.
Unit: 0.1 Hz
Sets the vibration suppression 2 correc-
UINT
tion.
Unit: %
Sets the anti-resonance control-related
UINT
selections.
Sets the anti-resonance frequency.
UINT
Unit: 0.1 Hz
Sets the anti-resonance gain correction.
UINT
Unit: %
Sets the anti-resonance damping gain.
UINT
Unit: %
Sets the anti-resonance filter time con-
INT
stant 1 correction.
Unit: 0.01 ms
Sets the anti-resonance filter time con-
INT
stant 2 correction.
Unit: 0.01 ms
16.3 DeviceNet Attributes
16.3.11 SERVOPACK Parameter Object
Continued from previous page.
Description
Continued on next page.
Value
10 to 20,000
500 to 2,000
0 to 10,000
0 to 10,000
10 to 2,500
10 to 2,500
0 to 10,000
10 to 20,000
500 to 2,000
10 to 2,000
10 to 1,000
0x0000 to
0x0011
10 to 20,000
1 to 1,000
0 to 300
-1,000 to
1,000
-1,000 to
1,000
16
16-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-oca04aSgdv-oca05a

Table of Contents