YASKAWA SGD7S Product Manual page 109

E-7-series
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

Terminal
Terminal Name
Symbols
Control power supply termi-
L1C, L2C
nals
Regenerative Resistor termi-
B1, B2
nals
You can use a single-phase, 100-VAC power supply input with the following models.
• SGD7S-R70F, -R90F, -2R1F, and -2R8F
4.3 Wiring the Power Supply to the SERVOPACK
4.3.1 Terminal Symbols and Terminal Names
Specifications and Reference
Single-phase, 100 VAC to 120 VAC, -15% to +10%,
50 Hz/60 Hz
4.3.5 Wiring Regenerative Resistors on page 4-22
If the regenerative capacity is insufficient, connect an External
Regenerative Resistor between B1/
Regenerative Resistor is not included. Obtain it separately.
Continued from previous page.
and B2. The External
4
4-13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-oca04aSgdv-oca05a

Table of Contents