YASKAWA SGD7S Product Manual page 231

E-7-series
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

6.14 Overheat Protection
6.14.2 Overheat Protection Selection
Using Overheat Protection in the Yaskawa Linear Servomotor
To use the overheat protection in the Yaskawa Linear Servomotor (SGLFW2), set Pn61A to

n.
An A.93B warning (Overheat Warning) will be detected if the overheat protection input (TH) sig-
nal from the Yaskawa SGLFW2 Linear Servomotor exceeds the warning temperature.
An A.862 alarm (Overheat Alarm) will be detected if the overheat protection input (TH) signal
from the Yaskawa SGLFW2 Linear Servomotor exceeds the alarm temperature.
Important
Monitoring the Machine's Temperature and Using Overheat
Protection
Set Pn61A = n.X to 2 or 3 to use overheat protection for the machine.
Set the following parameters as required.
Pn61B
Pn61C
Pn61D
Important
6-36
1.
• If the overheat protection input signal line is disconnected or short-circuited, an A.862 alarm
will occur.
• If you set Pn61A to n.1 (Use overheat protection in the Yaskawa Linear Servomotor), the
parameters in the Servomotor are enabled and the following parameters are disabled.
• Overheat Alarm Level (Pn61B)
• Overheat Warning Level (Pn61C)
• Overheat Alarm Filter Time (Pn61D)
Overheat Alarm Level
Setting Range
0 to 500
Overheat Warning Level
Setting Range
0 to 100
Overheat Alarm Filter Time
Setting Range
0 to 65,535
When Pn61A is set to n.
line is disconnected or short-circuited.
When Pn61A is set to n.
line is disconnected or short-circuited. To ensure safety, we recommend that you connect the
external circuits so that you can use a negative voltage input for the overheat protection input (an
analog voltage input).
Setting Unit
Default Setting
0.01 V
250
Setting Unit
Default Setting
1%
100
Setting Unit
Default Setting
1 s
0

2, an A.862 alarm will occur if the overheat protection input signal

3, an A862 alarm will not occur if the overheat protection input signal
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-oca04aSgdv-oca05a

Table of Contents