8.13 Manual Tuning
8.13.1 Tuning the Servo Gains
Pn140
Model Following Control Gain
The model following control gain determines the response characteristic of the servo system. If
you increase the setting of the model following control gain, the response characteristic will
improve and the positioning time will be shortened. The response characteristic of the servo
system is determined by this parameter, and not by Pn102 (Position Loop Gain).
Pn141
Information
Model Following Control Bias in the Forward Direction and Model Following Control Bias in
the Reverse Direction
If the response is different for forward and reverse operation, use the following parameters for
fine-tuning.
If you decrease the settings, the response characteristic will be lowered but overshooting will
be less likely to occur.
Pn143
Pn144
8-88
Parameter

n.
0
Do not use model following control.
(default setting)

n.
1
Use model following control.

n.
0
Do not perform vibration suppression.
(default setting)
Perform vibration suppression for a specific

n.
1
frequency.
Perform vibration suppression for two specific

n.
2
frequencies.
Model Following Control Gain
Setting Range
Setting Unit
10 to 20,000
For machines for which a high model following control gain cannot be set, the size of the
position deviation in model following control will be determined by the setting of the model
following control gain. For a machine with low rigidity, in which a high model following control
gain cannot be set, position deviation overflow alarms may occur during high-speed opera-
tion. If that is the case, you can increase the setting of the following parameter to increase
the level for alarm detection.
Use the following conditional expression for reference in determining the setting.
Maximum feed speed [reference units/s]
520 ≥
Pn
Pn
Position Deviation Overflow Alarm Level
Setting Range
Pn520
1 to
1,073,741,823
Model Following Control Bias in the Forward Direction
Setting Range
Setting Unit
0 to 10,000
Model Following Control Bias in the Reverse Direction
Setting Range
Setting Unit
0 to 10,000
Function
Default Setting
0.1/s
500
2.0
141/10 [1/s]
Setting Unit
Default Setting When Enabled Classification
1 reference
unit
Default Setting
0.1%
1,000
Default Setting
0.1%
1,000
When Enabled
Immediately
When Enabled
Immediately
5,242,880
Immediately
When Enabled
Immediately
When Enabled
Immediately
Classification
Tuning
Classification
Tuning
Setup
Classification
Tuning
Classification
Tuning

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-oca04aSgdv-oca05a

Table of Contents