YASKAWA SGD7S Product Manual page 125

E-7-series
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

When Using an Incremental Linear Encoder
The wiring depends on the manufacturer of the linear encoder.
 Connections to Linear Encoder from Heidenhain Corporation
Linear encoder from
Heidenhain Corporation
*
1
9
3
11
14
7
4
2
Connector
shell
Shield
*
represents a shielded twisted-pair cable.
 Connections to Linear Encoder from Renishaw PLC
Linear encoder from
Renishaw PLC
*
9
1
10
2
3
11
4
12
Connector
shell
Shield
*
represents a shielded twisted-pair cable.
Serial Converter Unit
CN2
CN1
*
COS
1
2
9
6
/COS
3
SIN
/SIN
11
14
REF
7
/REF
5V
4
1
2
0V
5
Connector
shell
Connector
shell
Shield
Serial Converter Unit
CN2
CN1
*
COS
9
2
1
6
/COS
10
SIN
2
/SIN
3
REF
/REF
11
5V
4
1
12
0V
5
Connector
shell
Connector
shell
Shield
4.4 Wiring Servomotors
4.4.3 Wiring the SERVOPACK to the Encoder
SERVOPACK
CN2
PS
5
U
/PS
6
V
W
PG5V
1
PG0V
2
Connector
shell
SERVOPACK
CN2
PS
5
U
/PS
6
V
W
1
PG5V
PG0V
2
Connector
shell
M
4
M
4-29