YASKAWA SGD7S Product Manual page 86

E-7-series
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

2.4 Examples of Standard Connections between SERVOPACKs and Peripheral Devices
2.3.3 DeviceNet Module External Dimensions and Connector Specifications
Linear Servomotors
Molded-case
circuit breaker
Noise Filter
External
Regenerative
Resistor * 2
*1.
This example is for a SERVOPACK with a three-phase, 200-VAC power supply input. The pin layout of the main
circuit connector depends on the voltage.
*2.
External Regenerative Resistors are not provided by Yaskawa.
2-28
Power supply
Three-phase, 200 VAC * 1
R S T
Magnetic Contactor
SERVOPACK
main circuit wires
Control
Power
Supply Cable
External
Regenerative
Resistor Cable
Ground
cable
SERVOPACK
CN5
CN3
CN7
CN6
CN1
CN8
CN2
Serial Converter
Unit Cable
Serial Converter Unit
Linear Encoder Cable
Linear Encoder
Linear Servomotor
Analog Monitor Cable
Digital Operator cable
Computer
Computer cable
DeviceNet
communications cable
I/O Signal Cable
When a Safety Function Is Not Used:
Leave the enclosed JZSP-CVH05-E
Safety Jumper Connector attached.
When a Safety Function Is Used:
Safety Function Device Cable
Safety function device
Sensor Cable
Digital
Operator
Support
Software
Host controller