Predefined user roles
network-admin
mdc-admin
Parameters
1: Uses format 1 for the NAS-Port-Id attribute.
2: Uses format 2 for the NAS-Port-Id attribute.
3: Uses format 3 for the NAS-Port-Id attribute.
4: Uses format 4 for the NAS-Port-Id attribute.
Usage guidelines
The NAS-Port-Id format supported by RADIUS servers varies by vendor. Use this command to
specify the format of the NAS-Port-Id attribute in the RADIUS packets sent for portal users to the
RADIUS server. The device then automatically constructs a value for the NAS-Port-Id attribute in the
specified format to meet the RADIUS server requirements.
Format 1 contains three space-separated strings: interface-type port-location access-node-id.
Spaces are not allowed within a string.
The interface-type string specifies the interface type of the NAS port. Available options include:
atm—ATM interface.
eth—Common Ethernet interface.
trunk—Ethernet trunk interface.
0—The interface type information will be reported by the access node to the BRAS.
The port-location string represents the location of the access line on the BRAS. Its format is
NAS_slot/NAS_subslot/NAS_port:XPI.XCI.
Field
NAS_slot
NAS_subslot
NAS_Port
XPI.XCI
For the access node to report its access line information to the BRAS, all fields will be set to 0s
except for the XPI and XCI fields.
The access-node-id string specifies the attributes the of BRAS. Its format is
AccessNodeIdentifier/ANI_rack/ANI_frame/ANI_slot/ANI_subslot/ANI_port:ANI_XPI.ANI_XCI,
in which the :ANI_XPI.ANI_XCI portion is optional.
AccessNodeIdentifier
ANI_rack
Description
Slot number of the BRAS, in the range of 0 to 31.
Subslot number of the BRAS, in the range of 0 to 31.
Port number of the BRAS, in the range of 0 to 63.
For ATM interfaces:
XPI is VPI in the range of 0 to 255.
XCI is VCI in the range of 0 to 65535.
For Ethernet interfaces or Ethernet trunk interfaces:
XPI is PVLAN in the range of 0 to 4095. This field is
set to 4096 if there is no PVLAN.
XCI is CVLAN in the range of 0 to 4095. This field is
set to 4096 if the user is not assigned to a VLAN as in
the situation where the end user device is directly
connected to a BRAS port.
Identifier description of the access node, a string not
longer than 50 characters without spaces.
Rack number of the access node, in the range of 0 to 15.
286