4203-E P-50
SECTION
2 POWER
ON/OFF
OPERATION
2.
Turning off the Power
Procedure:
(1)
Make sure that all machine actuators have been stopped.
(2)
Press the CONTROL OFF switch
to
turn it OFF.
If peripherals are connected
to
the NC, turn off power to these
peripherals.
QCOWTROL
OFF
: The NC backs up the data such as tool length offset data, cutter radius compensation
data, work
coordinate
system
offset data, and
parameter
data (excluding the
system
parameters)
in predetermined intervals. Therefore, if power is turned off
just
after
changing such data, the new data may not be backed up and the previous data might
remain unchanged.
In
such
a case, execute the backup command before turning off the power
to
ensure that the
data is changed without fail.
For backup operation, refer
to
III. DATA OPERATION, Section
1,
3-4-1. "Back Up
Command".
3.
Emergency Stop
If
it becomes necessary
to stop
the operation immediately,
press the EMG.
STOP switch.
The
machine
stops
immediately when the EMG. STOP switch is
pressed.
The
push-to-lock type switch
is locked if the switch
is pressed; to unlock
the
switch, turn it in the direction indicated by the
arrow symbol. After unlocking the
emergency
stop switch, reset
the NC and the NC is placed in the operation
ready state.
EMG. STOP
rm
s=