Download Print this page

Operation End Light (Option) - Okuma OSP-U100M Operation Manual

Cnc systems

Advertisement

4203-E P-111
SECTION
5
AUTOMATIC MODE OPERATION
(4) Initializing Library Program
Press function key [F1] (LIBRARY P.SET) and key in as follows:
LPI_I
;l [WRITE]
With the operation
above, the programs registered as library programs are all deleted.
(5)
Specifying Buffer Size of Library Program
Press function key [F1] (LIBRARY P.SET) and key in as follows:
LP
I_J
n;l [WRITE]
With the operation above, the buffer size of "n" bytes
for registering the library
programs
is ensured.
Note that when the buffer
size specification
is changed, the library program registration
state
and
the program selection state are all cleared.
To ensure the NC program registration area for
operation
without using library programs as
much as
practicable, zero the library program registration by the operation below.
Press function key [F1] (LIBRARY P. SET) and key in as follows:
LPI_J
0; I [WRITE]
The library programs registered in
the operations above, can
be accessed by the required MDI
mode operation. They can also be referenced in the S option mode or the equivalent operation
mode (DNC, for instance).
(6)
The subprograms in the file which have an extension LIB are automatically registered as library
programs when power supply
to the control is turned
on. Therefore, G code macro or other
subprograms which are frequently used are recommended
to be
stored
in
the LIB file. This
permits
them to be called any
time as
conventional G codes.
NOTICE
: (1) A library program is distinguished only by its program name. Therefore, it
is impossible to
register more than one library program which have the
same
name.
If the subprogram in the user program has the same name as the library program, the
library program is given priority when such a subprogram is intended
to be
called.
(2) Turn off and
on the power alter
adding a new library program.
19.
Operation End Light (Option)
The operation end light goes on when the following conditions have been satisfied. Note thatthe setting for
the related machine user
parameter must be set
"effective".
Mode
Condition
Automatic
operation
Single block off
When program is completed
(1)
schedule program after executing END
in
a schedule program.
(2)
main program after executing MOO, M01
,
M02 or M30 in a main program.
Restarting will
extinguish
the operation end light.
When the
alarm
occurs,
resetting the
CNC unit will extinguish the operation end
light.