Download Print this page

Machine System Parameters; Spindle Parameters - Okuma OSP-U100M Operation Manual

Cnc systems

Advertisement

4203-E P-454
SECTION
3
DESCRIPTION OF PARAMETER
AND
SETTING PROCEDURE
15.
Machine System Parameters
To display the MC SYSTEM PARAMETER (Screen Select) screen, set "1
"
for Machine System Parameter
on the MC USER PARAMETER
-
Screen select screen.
To display a
parameter, set "1"
for the
parameter
group on the MC SYSTEM PARAMETER
-
Screen Select
screen.
To disable the display of the MC SYSTEM PARAMETER (Screen Select) screen, set "0" for Machine
System Parameter on the MC USER
PARAMETER - Screen select screen,
or set "0" for a parameter
group which should
not be
displayed.
I
PARAMETER SET
97/07/15
14: 10:00
*
MC SYSTEM PARAMETER
*
Screen Select
[1=Active,
0=NegativeJ
m
i3.
T
14.
NO.
I
tem
NO.
I
tem
1. Spindle
2.ATC
3.APC
4.AAC
5.
Home Position
6.MCS
7. Power
Sequence
8. Ax is
Exchange
9.ATC
arm Parameter
10.ATC
arm
Torque limiter
15.
16.
17.
18.
19.
20.
21.
22.
11.
23.
12.
24.
[EXTEND]
SET
ADD
CAL
SEARCH
ITEM
t
ITEM
A
1 5-1
.
Spindle Parameters
Initial
Setting
Value
Effective
Command
Setting
Range
Setting
Display Screen
No.
Contents
Unit
Spindle Oscillate
Revolution
Sets the spindle oscillation
speed used for changing
spindle gear ranges.
ADD, SET
1
0 rpm
Oto 100
1
rpm
Spindle Oscillate
Frequency
Sets the length of time to
start
motor oscillation after
the output of
the gear
range
change solenoid signal for
spindle oscillation.
ADD, SET
2
1
sec
Oto 5
1
sec
Spindle Oscillate
Period
Sets the length
of motor
rotation time for spindle os¬
cillation.
3
ADD, SET
5 sec
Oto 5
1
sec
Torque
Limiter
Sets the
torque limit value
for spindle rotation.
(conversion with 32767
=
100%)
_
4
ADD, SET
1%
0 to
32767
1%
(327)

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Osp-u10m