Download Print this page

Nc Optional Parameter Spindle (Okuma Vac) - Okuma OSP-U100M Operation Manual

Cnc systems

Advertisement

4203-E P-416
SECTION 3 DESCRIPTION OF PARAMETER AND SETTING PROCEDURE
10.
NC Optional Parameter SPINDLE (OKUMA VAC)
This screen displays the
parameters to be used for the high-accuracy machining
function
and the
synchronized tapping function, which are allocated
to
NC optional parameter (bit), NC optional parameter
(word) and NC optional
parameter
(long word).
When the following
parameters are set,
the corresponding NC optional
parameters
are
set
accordingly.
Conversely, if NC optional parameters are
set,
the corresponding
parameters
shown below are
set
accordingly.
I
PARAMETER SET
T97/07/1
5
14:
10:00
SPI
NDLE(0KUMA VAC)
*NC
OPTIONAL
PARAMETER*
NO.
I
180000
I
1 SPINDLE ORIENT ZERO
OFFSET
2 ZERO OFFSET
(SYNC.
TAP)
3 IN-POSITION CHECK VALUE (SYNC.
TAP)
4
SPINDLE RATED
VALUE
(SYNC. TAP)
5
NUMBER OF TORQUE OVER TIME(Nx0. 01sec)
6
TORQUE
MONITOR START REVO. RAT 10 (JO
7
TORQUE
MONITOR DELAY TIME (0.1
sec)
8 RETURN SPEED OVERRIDES)
(SYNC. TAP)
9
684, G74
CONTROL SELECT
I ON (0:
FL0AT/1
:
SYNC.
)
0
20
0
0
0
0
0
1
Y
X
z
ACT POSIT
(WORK)
-0.001
-0.001
-0.001
ITEM
i
[EXTEND]
ITEM
t
SEARCH
SET
©©©©©©®@
(1)
SPINDLE ORIENT ZERO OFFSET (NC optional parameter (long word) No. 19)
Set the offset data used in spindle orientation for the spindle controlled by high-accuracy VAC.
Setting
unit: VAC command unit (1/1000
(deg) or
1/10000
(deg))
Setting range: 0 to 359999 (1/1
000 (deg))
O to
3599999 (1/10000 (deg))
Initial value:
0
(2)
ZERO OFFSET (NC optional parameter (long word)
No. 15)
Set the machine zero for spindle orientation applied
to the operation
which is called out by an E
command.
Setting unit: VAC command
unit
(1/1000 (deg)
or
1/10000
(deg))
Setting range: 0 to 359999 (1/1000 (deg))
0 to 3599999 (1/10000 (deg))
For normal spindle orientation commands (RS command), orientation operation
is
controlled using
the origin of the encoder.

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Osp-u10m