Download Print this page

Tape Tv Check; Tape Delimiter Code - Okuma OSP-U100M Operation Manual

Cnc systems

Advertisement

4203-E P-330
SECTION
3
DATA
INPUT/OUTPUT
OPERATION
(c) bit 2
Tape TV check
The
tape
TV check
is
a check on the number
of characters of tape data in each block of the
program.
It is checked that the number of codes from the code following one LF (EOB)
to
the next LF (EOB)
is an even number.
bit
2
Contents
0
In "READ" operations,
no TV check is performed.
In "PUNCH" operations,
the number of
characters
per block is
not
adjusted
.
In "READ" operations,
it is checked if the number of characters in each
block is an even number; if it is an odd number, an alarm occurs.
1
In "PUNCH"
operations, a
space is added if necessary to make the number
of characters in
one block
an even number.
(Initial value = 0)
(d) bit
3
Tape delimiter code
%/ER
Sets whether or
not
the
%/ER
code is used instead of
tape feed to
mark the
end of program
information on the
tape.
bit
3
Contents
Tape feed is taken to indicate the end of program data.
0
The
% (ER) code is taken to indicate
the
end of program data.
1
(Initial value = 0)
[Supplement]
The data up until the second appearance of an CR, and LF or EOB on the tape is
ignored.
(e) bit
4
Tape reading verification
Sets whether or
not
the program information
is automatically verified
when a
tape
is read.
bit
4
Contents
Verification is
not
performed
on completion
of a "READ" operation.
0
Verification is performed on completion of
a "READ" operation.
1
(Initial value = 0)
[Supplement]
File names are
not
verified.
(f)
bit 5
Tape rewind
Sets whether or not the tape is rewound after reading (if verification is
not performed).
bits
Contents
Operation
stops
after the tape has been read.
0
The tape is rewound after
it
has been read.
1
(Initial value = 0)
(g) bit 6
Special code alarm
Sets whether or not special codes ($20 to $5F, HT) trigger
an alarm.