Fixed Address Atc Specifications - Okuma OSP-U100M Operation Manual

Cnc systems

Advertisement

4203-E P-179
SECTION
1 DATA
SETTING
5-2-2.
Fixed Address ATC Specifications
To select a tool from the tools in the magazine using a tool number command, it is necessary to
set
the
correspondence between the tool numbers and the toolpot
numbers.
If an interference occurs between the tools stored in the
two
adjacent
toolpots due
to their diameters, set
the safety
adaptor
in toolpots
at
both sides of the toolpot which holds
a
large-diameter tool. This
prevents
an
occurrence
of interference between the tools during tool setting operations.
Setting:
i
TOOL
DATA~SEf
N_
1
I 97/07/15
14:10:00
*
POT
NO./
TOOL NO. TABLE
*
POT TOOL
NO.
NO.
11
011
12 012
13 013
14
014
15 015
16 016
17 017
18 018
19 019
20
NA
POT
TOOL
NO.
NO.
1 001
2
002
3 003
4 004
5 005
6 006
7
007
8 008
9 009
10l02ll
POT TOOL
POT TOOL
NO.
NO.
NO.
NO.
21
NA
22 022
23 023
24 024
25 025
26 026
27 027
28 028
29 029
30 030
TOOL
:ACT TOOL
:NXT TOOL
NA
020
007
:MAGAZINE
10
ITEM
t
ITEM
4
[EXTEND]
SEARCH
SET
(ZD©©©®©®©
(1)
Press the TOOL DATA key.
(2)
Press function key [F7] (ITEM
1).
The CRT will display the page of
"*POT NO./TOOL
NO.
TABLE*".
(3)
Locate the cursor at the TOOL NO. position of
the POT NO. for
which the tool
number is to
be
set.
(4)
Press function key [F1] (SET).
The CRT will display "S"
on
its console line. (I_I indicates the space.)
(5)
Key
in
the desired tool number through
the keyboard.
(a) Tool number
(b) Safety adaptor
(c) For clearing tool number