Download Print this page

Connection To Peripheral Devices; Btr System (No Dc Codes) - Okuma OSP-U100M Operation Manual

Cnc systems

Advertisement

4203-
E P-343
SECTION 3
DATA
INPUT/OUTPUT
OPERATION
3-5.
Connection
to
Peripheral Devices
If
an RS232C interface is
used, a special-purpose cable must be used
to
connect the signals that are
required by an
external device since the signals used
for the connection
vary
according to the external
device.
A
typical example is shown below.
3-5-1
.
BTR System (No DC Codes)
Example
1 :
NC
Peripheral device
FG
FG
TXD
RD
<
RXD
SD
RTS
CS
4
CTS
I/O BUSY/
4
DSRI
I/O ALARM/
SG
SG
RG1
READER START
DTR'
DR
Fig. 3-9 Connection for BTR System (No DC Codes) (1)
Since no EXT-INT
signal is used in this example, bit 1 of NC optional parameter (bit) No.
8 (No. 13,
14, 21 ,
22) (Ready signals of CNO: to CN4:)
should be
set to "1
"
in advance.
[Supplement]
(1) Timing Chart for READ
ra-igar
i
High
Ready
DSR
Low
High
Data
request
RG1
Low
\/
\/
Receive data
RXD
[
8 bits
Start bit
Stop bit
Fig. 3-10 Timing Chart
for READ [BTR System (No DC Codes)]

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Osp-u10m