Download Print this page

Reference Position Setting - Okuma OSP-U100M Operation Manual

Cnc systems

Advertisement

4203-E P-121
SECTION
6
DISPLAY ON NC OPERATION PANEL
(1)
Reference Position Setting
The reference
position is the
zero
point (in the
machine coordinate system) which is used
to
display
the relative actual position,
or, in
other words, the zero
point in
the relative coordinate
system.
The
reference
position can
be obtained by setting the coordinate value of the actual
position.
The reference position can be set in two different
manners: by
setting the actual position at "0" and
by
setting the actual position at a desired position.
To set the reference position, press function key [F8]
(EXTEND)
in the
automatic,
MDI, or manual
operation mode repeatedly until functions "RELATI. ZEROSET' and "RELATI.
PRESET' are
assigned to function keys [F2] and [F3], respectively.
=EX
=EX
=EX
RELATI.
RELATI.
ZEROSET
PRESET
[EXTEND]
J
(a) Setting the actual
position at "0"
Follow the procedure below when setting the actual position at
"0"
in the
relative coordinate
system.
1)
Press function key [F2]
(RELATI.
ZEROSET) in the automatic, MDI, or manual operation
mode.
The
prompt
"=
RPZS" will be displayed on the console line of the display
screen.
=EX
=EX
=EX
=RPZS
RELATI. RELATI.
ZEROSET
PRESET
[EXTEND]
J
FI I F2
[
F3
F4
[
F5
] (
F6
[
F7
F8
"RPZS" is displayed.
\
Press [F2] (RELATI. ZEROSET).

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Osp-u10m