Download Print this page

Mcs Parameters; Power Sequence; Axis Exchange Parameters - Okuma OSP-U100M Operation Manual

Cnc systems

Advertisement

4203-E
P-457
SECTION 3 DESCRIPTION OF PARAMETER AND SETTING PROCEDURE
Initial
Setting
Value
Effective
Command
Setting
Range
Setting
No.
Display Screen
Contents
Unit
The value of
automatic override
17
Sets the automatic override
value applied for home
posi-
tion return operation.
_
ADD, SET
0%
Oto 100
1%
15-6. MCS Parameters
Initial
Setting
Value
Effective
Command
Setting
Range
Setting
No.
Display Screen
Contents
Unit
MSC Charging Time
Sets the length
of time for
the
system
to wait for the
operation ready state of the
servo controller
(MSC).
1
ADD, SET
0
sec
Oto 30
1
sec
1 5-7. Power Sequence
Parameters
Initial
Setting
Value
Effective
Command
Setting
Range
Setting
Display Screen
No.
Contents
Unit
Compulsory Power
Shutdown Delay
Timer
Delay timer for shutting off
the power forcibly even if
all
of power shutdown condi¬
tions
are not
satisfied.
ADD, SET
1
0 sec
Oto
30
1
sec
Operating power
Shutdown Alarm
check Timer
Sets the length of waiting
time until the power is
shutdown after the start of
the operation
power
shutdown sequence.
Alarm message "4709
Alarm D Managing
operating power shutdown"
is displayed if the power is
not shut
off after the elapse
of the
set
time.
2
ADD, SET
0 sec
Oto
30
1 sec
15-8. Axis Exchange Parameters
Initial
Setting
Value
Effective
Command
Setting
Range
Setting
No.
Display Screen
Contents
Unit
Alarm
check timer for
LS exchange
Sets the length of time the
system waits for the input
from the axis exchange
complete LS.
1
ADD, SET
Osec
Oto 30
1
sec