4203-E P-171
SECTION
1
DATA SETTING
3-3-3.
Verify
The VERIFY operation occurs in the same manner as the READ operation. The data which is read is
not
determined by the parameter settings. There may be cases when an error occurs even though the
numeral displayed at "Parameter Set" is the same as that
at
the
verify data. However,
this
is due
simply
to
the fact that the number of digits following the displayed numeral are being held by the OSP, andthere
is
no
actual
error.
A
"tolerance"
designation can be made
at
the VERIFY operation as follows:
DV
Device name; file name; numeric value
By entering the optional tolerance (numeric value) designation, an error will
not
occur even if
a data
mismatch occurs,
provided that part of
the
parameter
data which is read is within the tolerance range. Only
positive integers can be designated as tolerance values. The
tolerance
system-of-units varies according
to
the
parameter types being
compared. Regarding data
items
with decimal points
(system parameters,
user
parameters,
zero
offset, tool data, etc.), comparison
will begin from the smallest displayed numeral
(following
decimal
point). Optional parameter words and long parameter words, etc., have no decimal
points, and are therefore compared
as they
are.
If the data
error value exceeds the
tolerance range, the following error message will be displayed:
5375 DATA
VERIFY ERROR "MISMATCH LINES"
The following
parameters
(including
the
tolerance
value)
are
compared during the
VERIFY
operation:
PNo.
Zero offset
Tool length offset
Cutter radius compensation
System parameter (excluding home position return order
data)
User
parameter
Thread pitch offset
NC
optional
parameter (long word)
NC optional
parameter
(word)
NC optional parameter (bit)
3-3-4.
Omitting the File Name and Device Name
-
If the device name is not specified at the READ and VERIFY operations, the setting will be determined by
optional parameter word No. 104 (initial value: 0, setting range: 0-11).
The devices which correspond to the setting values are shown below.
(This parameter setting becomes valid
when power
is
switched
ON.)
100
200
210
400
410
600
700
710
720
Setting Value
0
1
2
3
4
5
6
7
8
9
11
10
Device Name
TR
CN0 CN1 CN2 CN3 CN4
FD0
FD3
MD0 MD1
FD1
FD2
The "CN0" device name shown above represents the same device as the "TT" (teletyper) name.