DESCRIPTION OF PARAMETER AND SETTING PROCEDURE
9.
NC Optional Parameter RS232C
(CNO:)
This
screen displays the
parameters
to be used for the tape punch
interface function, which are allocated
to
NC optional parameter (bit) and NC optional parameter (word). Note that they are only for CNO: device
and it is necessary to set the
parameters
for the individual
NC optional parameter (bit) and NC optional
parameter (word)
screens for other devices.
When the following
parameters
are
set,
the corresponding NC optional
parameters
are
set
accordingly.
Conversely, if NC optional
parameters
are set, the corresponding parameters shown below are
set
accordingly.
I
PARAMETER SET
j
97/07/1
5 14:10:00
*NC OPTIONAL PARAMETER*
RS232C tCNO
:
J
NO.
1 STOP BJT(i:ibit/0:2bit)
2 PARITY CHECK(KYes/0:No)
3
PAR
ITY(1
: Even/0 :
Odd)
4
8 BIT JIS(1 :Yes/0:No)
5 DC C0DE(i:Yes/0:No)
6
DC CODE TYPE2(l:Yes/0:No)
7 FILE NAME
REQUEST at DNC-A(1:Yes/0:No)
8
MASTER/SLAVE
or RS CONT.
0
:SLV,Yes/0:MAS.No)
9 BAUD
RATE
(bps)
10
BUSY TlME(sec)
99999
99999
X
z
Y
ACT POSIT
(WORK)
300.000
100.010
100.000
ITEM
T
ITEM!
[EXTEND]
SET
SEARCH
©©©©©©©©
(1)
STOP BIT (1:1bit/0:2bit) (NC optional parameter (bit) No.
8,
bit
0)
RS232C
stop bit check
= 0 :
Stop
bit 2
=
1 :
Stop bit
1
(2)
PARITY CHECK (1 :Yes/0:No) (NC optional parameter
(bit)
No. 8, bit 2)
RS232C
parity check (sets whether or not a parity bit is added to 8-bit data)
=
0
:
No parity
= 1 : Parity check
(3)
PARITY (1
:Even/0:Odd) (NC
optional
parameter
(bit)
No. 8,
bit 3)
RS232C odd
parity
scheme
=
0 :
Odd parity
= 1 :
Even parity